Use the EMC VNX direct driver to create, attach, detach, and
delete volumes, create and delete snapshots, and so on. This driver
is based on the Cinder-defined ISCSIDriver
driver.
To complete volume operations, the driver uses the NaviSec command-line interface (CLI) to communicate with back-end EMC VNX storage.
Flare version 5.32 or later.
You must activate VNX Snapshot and Thin Provisioning license for the array. Ensure that all the iSCSI ports from the VNX are accessible through OpenStack hosts.
Navisphere CLI v7.32 or later.
EMC storage VNX Series are supported.
Create volume
Delete volume
Attach volume
Detach volume
Create snapshot
Delete snapshot
Create volume from snapshot
Create cloned volume
Copy image to volume
Copy volume to image
Extend volume
Complete these high-level tasks to set up the VNX direct driver:
Install NaviSecCLI. You must install the NaviSecCLI tool on the controller node and all the Cinder nodes in an OpenStack deployment. See the section called “Install NaviSecCLI”.
Register with VNX. See the section called “Register with VNX”
On Ubuntu x64, download the NaviSecCLI deb package from EMC's OpenStack Github web site.
For all the other variants of Linux, download the NaviSecCLI rpm package from EMC's support web site for VNX2 series or VNX1 series. Login is required.
To export a VNX volume to a compute node or a volume node, you must register the node with VNX.
Procedure 1.1. To register the node
On the compute node or volume node
1.1.1.1
, do the following (assume10.10.61.35
is the iSCSI target):# /etc/init.d/open-iscsi start # iscsiadm -m discovery -t st -p 10.10.61.35 # cd /etc/iscsi # more initiatorname.iscsi # iscsiadm -m node
Log in to VNX from the node using the target corresponding to the SPA port:
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.a0 -p 10.10.61.35 -l
Where
iqn.1992-04.com.emc:cx.apm01234567890.a0
is the initiator name of the node. Login to Unisphere, go toVNX00000
->Hosts->Initiators, Refresh and wait until initiatoriqn.1992-04.com.emc:cx.apm01234567890.a0
with SP PortA-8v0
appears.Click CLARiiON/VNX, and enter the host name
, selectmyhost1
and IP addressmyhost1
. Click . Now host1.1.1.1
also appears under Hosts->Host List.Log out of VNX on the node:
# iscsiadm -m node -u
Log in to VNX from the node using the target corresponding to the SPB port:
# iscsiadm -m node -T iqn.1992-04.com.emc:cx.apm01234567890.b8 -p 10.10.10.11 -l
In Unisphere register the initiator with the SPB port.
Log out:
# iscsiadm -m node -u
Make the following changes in
/etc/cinder/cinder.conf
.
For the VNX iSCSI driver, add the following entries, where
10.10.61.35
is the IP address
of the VNX iSCSI target, 10.10.72.41
is the IP address of the VNX array (SPA or SPB),
default_timeout
is the default
time out for CLI operations in minutes, and
max_luns_per_storage_group
is
the default max number of LUNs in a storage group:
iscsi_ip_address = 10.10.61.35 san_ip = 10.10.72.41 san_login = global_username san_password = password naviseccli_path = /opt/Navisphere/bin/naviseccli storage_vnx_pool_name = poolname default_timeout = 10 max_luns_per_storage_group=256 volume_driver=cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver
Note | |
---|---|
To find out |
Restart the cinder-volume
service.
Volume type support allows user to choose thick/thin provisioning capabilities.
Here is an example of how to setup volume type. First create volume types. Then define extra specs for each volume type.
Procedure 1.2. To set up volume types
Setup volume types:
$ cinder type-create "TypeA" $ cinder type-create "TypeB"
Setup volume type extra specs:
$ cinder type-key "TypeA" set storagetype:provisioning=thick $ cinder type-key "TypeB" set storagetype:provisioning=thin
The previous example creates two volume types:
TypeA
and TypeB
.
For TypeA
, storagetype:provisioning
is set to thick
. Similarly
for TypeB
, storagetype:provisioning
is set to thin
. If
storagetype:provisioning
is not specified, it will be
default to thick
.